Smart Relay-Based Control System for Reverse Osmosis Drinking Water Treatment

Sistem Pengendalian Berbasis Relay Cerdas untuk Pengolahan Air Minum dengan Teknologi Osmosis Terbalik
Vol. 2 No. 2 (2025): Oktober:

Mochammad Armadani (1), Syamsudduha Syahrorini (2)

(1) Program Studi Teknik Elektro, Universitas Muhammadiyah Sidoarjo, Indonesia, Indonesia
(2) Program Studi Teknik Elektro, Universitas Muhammadiyah Sidoarjo, Indonesia, Indonesia
Fulltext View | Download

Abstract:

General Background: Access to safe drinking water remains a critical challenge in Indonesia, with nearly 30% of the population lacking proper access. Specific Background: Reverse Osmosis (RO) technology provides a solution for producing clean water, but conventional systems still face issues of efficiency, reliability, and safety. Knowledge Gap: Limited studies document the integration of automated control systems with RO units in real-world industrial applications. Aim: This study aims to develop and test a drinking water treatment control system using Schneider Smart Relay integrated with pH and TDS sensors. Results: Experiments on four water samples showed average pH of 7.67 (input), 7.80 (reject), and 7.86 (output), while average TDS values were 136 ppm (input), 298 ppm (reject), and 33.5 ppm (output). The system automatically activated or deactivated pumps according to preset water quality parameters, with buzzer alerts for anomalies, ensuring compliance with health standards. Novelty: The system combines automation, energy efficiency, and safety through smart relay integration, offering advantages over conventional RO setups. Implications: Findings demonstrate that this system can improve water treatment reliability and is suitable for household and industrial-scale implementation.


Highlight:



  1. Automated RO system improved efficiency and water quality control

  2. Smart relay integration ensured safety and energy savings

  3. Applicable for household and industrial water treatment needs


Keywords: Reverse Osmosis, Smart Relay, Drinking Water, pH Sensor, TDS Sensor

References

[1] J. Prayitno, “Aspek Mikrobiologi dalam Pengolahan Air Siap Minum Menggunakan Membran Reverse Osmosis,” vol. 12, no. 2, pp. 175–184, 2019.

[2] “Rancang_Bangun_Alat_Filtrasi_Penyedia_Air_Siap_Min.”

[3] “Automatization of Ultrafiltration Pump Control and Reverse Osmosis High Pressure Pump on Ready to Drink Water Unit Using Schneider Zelio Smart Relay.” [Online]. Available: https://www.antaranews.com/berita/19604

[4] F. Zulfiryansyah et al., “Air Quality Monitoring System Using Unmanned Aerial Vehicle (UAV) Quadcopter Type,” 2022.

[5] Y. T. Pratama, J. Jamaaluddin, S. D. Ayuni, and I. Anshory, “Monitoring Oil Water Separator on Ship Based on Microcontroller Arduino Mega 2560,” in SNESTIK Seminar Nasional Teknik Elektro, Sistem Informasi, dan Teknik Informatika, 2024, doi: 10.31284/p.snestik.2024.5907.

[6] Ma. Shidiq, “Perancangan Otomasi Sistem Pengolahan Air Payau Menjadi Air Minum dengan Prinsip Reverse Osmosis Berbasis Microcontroller.”

[7] R. Ramdani et al., “Perancangan Panel Motor Control Center Reverse Osmosis Water System.”

[8] F. Zulfiryansyah et al., “Air Quality Monitoring System Using Unmanned Aerial Vehicle (UAV) Quadcopter Type,” 2022.

[9] R. Ramdani et al., “Perancangan Panel Motor Control Center Reverse Osmosis Water System.”

[10] P. Siahaan, N. Sinaga, and J. Windarta, “Model Proses Pengolahan Air Laut Metode Reverse Osmosis Memanfaatkan Sumber Energi Sinar Surya,” ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika, vol. 10, no. 3, p. 609, Jul. 2022, doi: 10.26760/elkomika.v10i3.609.

[11] I. D. M. J. Putra, I. Sulistiyowati, and S. Syahrorini, “Hot Water Looping System to Control Temperature of Drug Production Based on Arduino,” 2022.

[12] “WhatsApp Image 2024-11-17 at 13.04.11_ad60da53.”

[13] T. A. Dewi and M. Rifa, “Pengaturan Kontrol PID pada Proses Reverse Osmosis Pengolahan Air Laut dengan Sistem SCADA.”

[14] Y. P. Wulandari, A. Kriswantriyono, N. S. Pasila, E. Y. Hermitasari, and R. D. Pratama, “Teknologi Pengolahan Air Bersih pada Program Water Supply System (WSS) Desa Saliki,” vol. 7, no. 1, pp. 15–24, 2022.

[15] I. D. M. J. Putra, I. Sulistiyowati, and S. Syahrorini, “Hot Water Looping System to Control Temperature of Drug Production Based on Arduino,” 2022.

[16] E. A. S. Aji, J. Jamaaluddin, A. Ahfas, and S. D. Ayuni, “Leak Monitoring in Split Duct Air Conditioner Based on Internet of Things,” JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA), vol. 7, no. 2, pp. 176–187, Nov. 2023, doi: 10.21070/jeeeu.v7i2.1678.

[17] F. Febrianti, S. A. Wibowo, and N. Vendyansyah, “Implementasi IoT Monitoring Kualitas Air dan Sistem Administrasi pada Pengelola Air Bersih Skala Kecil,” 2021.

[18] A. Sujiwa and S. Rochman, “Pengembangan Sistem Kontrol serta Monitoring Suhu dan Volume Air Berbasis Web pada Perangkat Desalinasi Air Laut,” in SNHRP-II UNIPA Surabaya. [Online]. Available: http://snhrp.unipasby.ac.id/